Model 8800 Specifications
1
2
3
4
5
6
7
8
EXTERNAL SUPPLY TERMINALS FOR REMOTE CONTROL WIRING
COOL AIR INLET FOR Tx FITTED WITH AUTOMATICALLY OPENING LOUVRES
A
A
COOL AIR INLET FOR LOAD BANK FITTED WITH AUTOMATICALLY OPENING LOUVRES
EXHAUST FANS FOR TRANSFORMER COOLING FITTED WITH AUTOMATICALLY OPENING LOUVRES
ACCESS TO PERSONNEL AREA
INSPECTION ACCESS FOR LOAD BANK
2591.0 [102]
A
B
B
2438.0 [96] 2260.0 [89] (TWISTLOCK CENTRES)
5855.0 [230 1
2 ] (TWISTLOCK CENTRES)
2689.5 [105 7 8 ]
CABLE ACCESS FOR HV POWER CABLES (SEE DETAIL)
405.8 [16]
ACCESS TO HV CONNECTIONS AND Tx
6058.0 [238 1 2 ]
COOL AIR INLET FOR LOAD BANK FITTED WITH AUTOMATICALLY OPENING LOUVRES
PRIMARY HV CABLE ENTRY WITH DIRECT ACCESS TO HV CT's (SEE DETAIL)
2350.0 [92 1 2 ]
337.0 [13 1 4 ]
105.0 [4 1 8 ]
230.0 [9]
C
C
380.0 [15]
230.0 [9]
FLOOR ACCESS FOR CONTROL CABLES FITTED WITH BLANK ALUMINIUM GLAND PLATE 380x200mm CLEAR AREA
750.0 [29 1 2 ]
200.0 [7 7 8 ]
380.0 [15]
FLOOR ACCESS FOR HV CABLES FITTED WITH BLANK ALUMINIUM GLAND PLATE 380x700mm CLEAR AREA
A ( 1 : 12 )
700.0 [27 1 2 ]
230.0 [9]
130.5 [5 1 8 ]
D
D
337.0 [13 1 4 ]
HV CABLE ACCESS VIA TRANSIT BLOCK SYSTEM SUPPLIED WITH DETACHABLE SHIPPING COVER CUSTOMER TO SUPPLY INDIVIDUAL BLOCKS TO SUIT OWN CABLE SIZES. MORE INFORMATION CAN BE FOUND AT THE SUPPLIERS WEBSITE - www.roxtec.com
TRANSFORMER (Tx)
HOT AIR EXHAUST FOR LOAD BANK
218.0 [8 5 8 ]
All dimensions are in millimeters. Specifications subject to change without notice.
120.5 [4 3 4 ]
E
E
1 An additional heater is located in the control cabinet and powered from the isolated 110-120V control circuit supply. Internal Lighting Bulkhead fittings are provided to give illumination inside the containers. Lights are sited in the control room and the HV power connection area/Transformer compartment. As this equipment is often utilised for hire and often night-time working the supplied lighting makes the working environment user friendly. Power for the lighting is supplied from either the single-phase auxiliary supply or from the fan and control circuit supply. A three-position switch enables quick and easy selection on moveable load banks and an on/off switch is fitted to static. Internal Single Phase Socket Outlets The control room is equipped with single phase socket outlets. These may be used to power a PC to operate the load bank. International load banks are fitted with two sockets. One is a 13 amp square pin, the other a European round pin socket. One 5 amp RCD protection device backs both units. Load banks to North American specification are supplied with one US type 2 flat blade and earth socket backed by a RCD protection device. 2 3 MAX WEIGHT Approx - 18000kg Anti-Condensation Heaters Anti-condensation heaters are fitted within the control and switch gear cabinets and controlled by thermostats. NOTE: AT LEAST 2 METERS OF CLEAR AREA SHOULD BE LEFT AROUND THE LOAD BANK FOR DOOR OPENINGS AND COOL AIR INLETS Avtron Power Solutions NJ Froment & Co Ltd, Cliffe Road, Easton-on-the-Hill, Stamford, PE9 3NP, UK
Options Ring Main Unit (RMU)
6 Avtron load banks comply with international standards and are CE marked to confirm compliance with both the EMC and Low Voltage Directives. 7 8 GENERAL ASSEMBLY - SHOALWATER BAY 8800 LOAD BANK Testing and Standards Functional operation and load tests are completed on all load banks, before despatch, in line with our ISO 9001:2008 procedures. CAD Code. 8800 Load Bank Part Number. N/A Drg No. 03762D01 Sheet 1 of 1 Scale. NTS 1st Angle Projection Dims. mm REVISION HISTORY DESCRIPTION B 23/03/2022 MJM C HEATING AND LIGHTING NOTES REMOVED, LV CONNECTION DETAILS REMOVED, WEIGHT AMMENDED 18/08/2022 MJM D EXTRA FLOOR APERTURE ADDED FOR CONTROL CABLE ENTRY 17/10/2022 MJM EXTERNAL FAN & CONTROL REMOVED, 'OPTIONAL' LV ADDED & TITLE CHANGE
REV
DATE APPROVED
4 An RMU complying to IEC standards allow the integrated transformer to be fully isolated from the supply on test. The RMU provides short circuit and time delay fault protection. A shunt trip facility is also fitted to allow tripping from a remote location. For further information on the RMU please contact your local Avtron representative. Air Inlet Louvre Covers Metal hinged covers may be fitted over the louvers on the sides and ends of the container to prevent rain and road dirt from entering in harmful quantities during long distance transportation. Top hinged when closed they are secured shut by key operated latches. For load bank operation all covers must be opened and are held in position by gas struts. The overall dimensions of the standard ISO 5 Drawn - M J Musgrave Checked - Approved - NJ Froment & Co Ltd Easton on the Hill STAMFORD - PE9 3NP - UK Tel: +44 (0) 1780 480033 Fax: +44 (0) 1780 480044 loadbanks@ascopower.com
© NJ Froment & Co. Ltd. This document may not be copied or disclosed in whole or part without prior written authority.
F
F
Date - 16/03/2022
Date -
Date -
Weight and Dimensions Measurements: mm/in. and kg/lbs. Model 8800 Length 6100/240.15 Width 2440/96.06 Height 2590/101.97 Weight
Dependent on capacity
Additional Information An extensive range of resistive, inductive, capacitive or combined load banks of varying capacities are also available. For further information on this model or any other 8000 SERIES load bank, please contact a member of our sales team.
container are maintained. Documentation – Operator Handbook
A comprehensive illustrated operator’s manual is supplied. Sections cover safety, installation, commissioning, operation, calibration, maintenance and fault finding.
www.avtronpower.com customercare@avtronpower.com • +44 (0) 1780 480033 ©2023 Avtron Power Solutions. Publication 5067 • Rev. J