Model 8400 Specifications

A

A

HOT AIR DISCHARGE

HOT AIR DISCHARGE

HOT AIR DISCHARGE

HOT AIR DISCHARGE

HOT AIR DISCHARGE

HOT AIR DISCHARGE

2591 [102.0]

B

B

COOL AIR FLOW IN

COOL AIR FLOW IN

COOL AIR FLOW IN

COOL AIR FLOW IN

COOL AIR FLOW IN

394 [15.5]

650.5 [25.6]

x8 ELECTRICAL OPERATED AIR INLET LOUVRES

MAINTENANCE ACCESS DOORS

MAINTENANCE ACCESS DOORS

MAINTENANCE ACCESS SIDE DOORS

705 [27.8]

2677 [105.4] CABLE ENTRY GLAND PLATE POSITION

2632 [103.6]

WALK IN CONTROL ROOM

LOUVRE MAINTENANCE DOOR FOR OPERATING MECHANISM

2050 [80.7] FORK LIFT POCKET CENTRES

FOR FAN & CONTROLS CABLE ENTRY APERTURE - 220[8.7] X 220[8.7] CLEAR AREA FITTED WITH WEATHER SOCK

C

C

FLOOR ENTRY GLAND PLATE APERTURE 960[37.8] X250[9.8]

3029 [119.3]

300 [11.8]

FORK LIFT POCKET DETAIL

2438 [96.0]

D

D

CABLE ENTRY DETAIL

1905 [75.0] DUCT OPENING

115 [4.5]

LOCKABLE LIFT UP CABLE ENTRY DOOR

1093 [43.0] DUCT OPENING

355 [14.0]

210 [8.3]

6058 [238.5]

466 [18.3]

E

E

NOTE : 2M OF CLEAR SPACE SHOULD BE LEFT AROUND THE LOADBANK FOR COOL AIR INLET AND MAINTENANCE ACCESS. AT LEAST 5M SHOULD BE LEFT CLEAR BETWEEN HOT AIR OUTLET AND ANY SURFACE.

FOR MAIN POWER CABLE ENTRY x2 APERTURE - 605[23.8] X 288[11.3] CLEAR AREA FITTED WITH WEATHER SOCK

All dimensions are in millimeters. Specifications subject to change without notice.

16500 KGS / 36376 LBS

APPROX WEIGHT - 8400

© NJ Froment & Co. Ltd. This document may not be copied or disclosed in whole or partwithout prior written authority.

REVISION HISTORY

NJ Froment & Co Ltd Easton on the Hill STAMFORD - PE9 3NP - UK Tel: +44 (0) 1780 480033 Fax: +44 (0) 1780 480044 loadbanks.ascopower.com

8400 GENERAL_ARRANGEMENT_MOVABLE

CAD Code. 8400 Part Number. N/A Drg No. Sheet

F

F

REV

DATE

APPROVED

DESCRIPTION

Drawn - RPM

Date - 29/09/2021

1 Internal Lighting Bulkhead fittings are provided to give illumination inside the containers. Lights are sited in the control room, behind service access doors and the main power connection area. As this equipment is often utilised for hire and often night-time working the supplied lighting makes the working environment user friendly. Power for the lighting is supplied from either the single-phase auxiliary supply or from the fan and control circuit supply. A three-position switch enables quick and easy selection on moveable load banks and an on/off switch is fitted to static. Internal Single Phase Socket Outlets The control room is equipped with single phase socket outlets. These may be used to power a PC to operate the load bank. International load banks are fitted with two sockets. One is a 13 amp square pin, the other a European round pin socket. One 5 amp RCD protection device backs both units. Load banks to North American specification are supplied with one US type 2 flat blade and earth socket backed by a RCD protection device. 2 3

4 Options Power Isolation

7 Weight and Dimensions Measurements: mm/in. and kg/lbs. Model 8400 Length 6100/240.15 Width 2440/96.06 Height 2590/101.97 Weight 8 Scale. NTS 1st Angle Projection Dims. mm[in]

1_OF_1 GAS8400A01

Checked - Date - Approved - RPM Date - 16/02/2022

5

6

Power air circuit breakers complying to IEC standard allow the load bank to be fully isolated from the supply on test. The circuit breakers provide short circuit, overload and earth fault protection. A shunt trip facility is also fitted to allow tripping from a remote location. Dual UL/IEC standard circuit breakers are also available. Documentation – Operator Handbook A comprehensive illustrated operator’s manual is supplied. Sections cover safety, installation, commissioning, operation, calibration, maintenance and fault finding. Testing and Standards Functional operation and load tests are completed on all load banks, before despatch, in line with our ISO 9001:2008 procedures. Avtron load banks comply with international standards and are CE marked to confirm compliance with both the EMC and Low Voltage Directives.

Dependent on capacity

Additional Information An extensive range of resistive, inductive, capacitive or combined load banks of varying capacities are also available. For further information on this model or any other 8000 SERIES load bank, please contact a member of our sales team.