Avtron Power Solutions Digital Binder
1
2
3
4
5
6
7
8
Model 8400 Specifications
A
A
HOT AIR DISCHARGE
HOT AIR DISCHARGE
HOT AIR DISCHARGE
HOT AIR DISCHARGE
HOT AIR DISCHARGE
HOT AIR DISCHARGE
2591 [102.0]
B
B
COOL AIR FLOW IN
COOL AIR FLOW IN
COOL AIR FLOW IN
COOL AIR FLOW IN
COOL AIR FLOW IN
394 [15.5]
650.5 [25.6]
x8 ELECTRICAL OPERATED AIR INLET LOUVRES
MAINTENANCE ACCESS DOORS
MAINTENANCE ACCESS DOORS
MAINTENANCE ACCESS SIDE DOORS
705 [27.8]
2677 [105.4] CABLE ENTRY GLAND PLATE POSITION
2632 [103.6]
WALK IN CONTROL ROOM
LOUVRE MAINTENANCE DOOR FOR OPERATING MECHANISM
2050 [80.7] FORK LIFT POCKET CENTRES
FOR FAN & CONTROLS CABLE ENTRY APERTURE - 220[8.7] X 220[8.7] CLEAR AREA FITTED WITH WEATHER SOCK
C
C
FLOOR ENTRY GLAND PLATE APERTURE 960[37.8] X250[9.8]
3029 [119.3]
300 [11.8]
FORK LIFT POCKET DETAIL
2438 [96.0]
D
D
CABLE ENTRY DETAIL
1905 [75.0] DUCT OPENING
115 [4.5]
LOCKABLE LIFT UP CABLE ENTRY DOOR
1093 [43.0] DUCT OPENING
355 [14.0]
210 [8.3]
6058 [238.5]
466 [18.3]
E
E
NOTE : 2M OF CLEAR SPACE SHOULD BE LEFT AROUND THE LOADBANK FOR COOL AIR INLET AND MAINTENANCE ACCESS. AT LEAST 5M SHOULD BE LEFT CLEAR BETWEEN HOT AIR OUTLET AND ANY SURFACE.
FOR MAIN POWER CABLE ENTRY x2 APERTURE - 605[23.8] X 288[11.3] CLEAR AREA FITTED WITH WEATHER SOCK
All dimensions are in millimeters. Specifications subject to change without notice.
16500 KGS / 36376 LBS
APPROX WEIGHT - 8400
© NJ Froment & Co. Ltd. This document may not be copied or disclosed in whole or partwithout prior written authority.
REVISION HISTORY
NJ Froment & Co Ltd Easton on the Hill STAMFORD - PE9 3NP - UK Tel: +44 (0) 1780 480033 Fax: +44 (0) 1780 480044 loadbanks.ascopower.com
8400 GENERAL_ARRANGEMENT_MOVABLE
CAD Code. 8400 Part Number. N/A Drg No. Sheet
F
F
REV
DATE
APPROVED
DESCRIPTION
Drawn - RPM
Date - 29/09/2021
1 Internal Lighting Bulkhead fittings are provided to give illumination inside the containers. Lights are sited in the control room, behind service access doors and the main power connection area. As this equipment is often utilised for hire and often night-time working the supplied lighting makes the working environment user friendly. Power for the lighting is supplied from either the single-phase auxiliary supply or from the fan and control circuit supply. A three-position switch enables quick and easy selection on moveable load banks and an on/off switch is fitted to static. Internal Single Phase Socket Outlets The control room is equipped with single phase socket outlets. These may be used to power a PC to operate the load bank. International load banks are fitted with two sockets. One is a 13 amp square pin, the other a European round pin socket. One 5 amp RCD protection device backs both units. Load banks to North American specification are supplied with one US type 2 flat blade and earth socket backed by a RCD protection device. 2 3
4 Options Power Isolation
7 Weight and Dimensions Measurements: mm/in. and kg/lbs. Model 8400 Length 6100/240.15 Width 2440/96.06 Height 2590/101.97 Weight 8 Scale. NTS 1st Angle Projection Dims. mm[in]
1_OF_1 GAS8400A01
Checked - Date - Approved - RPM Date - 16/02/2022
5
6
Power air circuit breakers complying to IEC standard allow the load bank to be fully isolated from the supply on test. The circuit breakers provide short circuit, overload and earth fault protection. A shunt trip facility is also fitted to allow tripping from a remote location. Dual UL/IEC standard circuit breakers are also available. Documentation – Operator Handbook A comprehensive illustrated operator’s manual is supplied. Sections cover safety, installation, commissioning, operation, calibration, maintenance and fault finding. Testing and Standards Functional operation and load tests are completed on all load banks, before despatch, in line with our ISO 9001:2008 procedures. Avtron load banks comply with international standards and are CE marked to confirm compliance with both the EMC and Low Voltage Directives.
Dependent on capacity
Additional Information An extensive range of resistive, inductive, capacitive or combined load banks of varying capacities are also available. For further information on this model or any other 8000 SERIES load bank, please contact a member of our sales team.
Avtron Power Solutions NJ Froment & Co Ltd, Cliffe Road, Easton-on-the-Hill, Stamford, PE9 3NP, UK
www.avtronpower.com customercare@avtronpower.com • +44 (0) 1780 480033 ©2023 Avtron Power Solutions. Publication 5024 • Rev. J
Made with FlippingBook - Online magazine maker