1 Model 8300 Specifications 2

3

4

5

6

7

8

A

A

HOT AIR DISCHARGE

HOT AIR DISCHARGE

HOT AIR DISCHARGE

HOT AIR DISCHARGE

B

B

2591 [102.0]

COOL AIR FLOW IN

COOL AIR FLOW IN

COOL AIR FLOW IN

COOL AIR FLOW IN

COOL AIR FLOW IN

380 [15.0]

SIGMA HAND HELD CABLE ENTRY

436 [17.2]

C

C

x4 ELECTRICAL OPERATED AIR INLET LOUVRES

1000 [39.4]

MAINTENANCE ACCESS SIDE DOORS

MAINTENANCE ACCESS DOORS

CABLE ENTRY GLAND PLATE POSITION

FORK LIFT POCKET CENTRES

WALK IN CONTROL ROOM

LOUVRE MAINTENANCE DOOR FOR OPERATING MECHANISM

EXTERNAL FAN AND CONTROL SUPPLY INLET

515 [20.3]

FLOOR ENTRY GLAND PLATE APERTURE 570[22.4] X 270[10.6]

CABLE ENTRY DETAIL

FORK LIFT POCKET DETAIL

290 [11.4]

D

D

90 [3.5]

LOCKABLE LIFT UP CABLE ENTRY DOOR

305 [12.0]

1905 [75.0] DUCT OPENING

2438 [96.0]

210 [8.3]

FOR MAIN POWER CABLE ENTRY APERTURE 435[17.1] X 210[8.3] CLEAR AREA FITTED WITH WEATHER SOCK

E

E

435 [17.1]

1093 [43.0] DUCT OPENING

2991 [117.8]

NOTE : 2M OF CLEAR SPACE SHOULD BE LEFT AROUND THE LOADBANK FOR COOL AIR INLET AND MAINTENANCE ACCESS. AT LEAST 5M SHOULD BE LEFT CLEAR BETWEEN HOT AIR OUTLET AND ANY SURFACE.

All dimensions are in millimeters. Specifications subject to change without notice.

APPROX WEIGHT - 8300

3.3MVA - 8500 KG / 18750 LB 2.5MVA - 8000 KG / 17650 LB 1.7MVA - 6500 KG / 14350 LB

© NJ Froment & Co. Ltd. This document may not be copied or disclosed in whole or partwithout prior written authority.

REVISION HISTORY

NJ Froment & Co Ltd Easton on the Hill STAMFORD - PE9 3NP - UK Tel: +44 (0) 1780 480033 Fax: +44 (0) 1780 480044 loadbanks.ascopower.com

8300 GENERAL_ARRANGEMENT_MOVABLE

CAD Code. Part Number. N/A Drg No. Sheet

F

F

DESCRIPTION

REV

DATE

APPROVED

Drawn - RPM

Date - 20/10/2021

1_OF_1 GAM8300A01

Checked - Date - Approved - RPM Date - 16/02/2022

Scale. NTS 1st Angle Projection

Dims. mm[in]

1 Internal Lighting Bulkhead fittings are provided to give illumination inside the containers. Lights are sited in the control room, behind service access doors and the main power connection area. As this equipment is often utilised for hire and often night-time working the supplied lighting makes the working environment user friendly. Power for the lighting is supplied from either the single-phase auxiliary supply or from the fan and control circuit supply. A three-position switch enables quick and easy selection on moveable load banks and an on/off switch is fitted to static. Internal Single Phase Socket Outlets The control room is equipped with single phase socket outlets. These may be used to power a PC to operate the load bank. International load banks are fitted with two sockets. One is a 13 amp square pin, the other a European round pin socket. One 5 amp RCD protection device backs both units. Load banks to North American specification are supplied with one US type 2 flat blade and earth socket backed by a RCD protection device. 2

Options Power Isolation

6 Weight and Dimensions Measurements: mm/in. and kg/lbs. Model 8300 Length 3000/118.11 Width 2440/96.06 Height 2590/101.97 Weight 7

3

4

5

8

Power air circuit breakers complying to IEC standard allow the load bank to be fully isolated from the supply on test. The circuit breakers provide short circuit, overload and earth fault protection. A shunt trip facility is also fitted to allow tripping from a remote location. Dual UL/IEC standard circuit breakers are also available. Documentation – Operator Handbook A comprehensive illustrated operator’s manual is supplied. Sections cover safety, installation, commissioning, operation, calibration, maintenance and fault finding. Testing and Standards Functional operation and load tests are completed on all load banks, before despatch, in line with our ISO 9001:2008 procedures. Avtron load banks comply with international standards and are CE marked to confirm compliance with both the EMC and Low Voltage Directives.

Dependent on capacity

Additional Information An extensive range of resistive, inductive, capacitive or combined load banks of varying capacities are also available. For further information on this model or any other 8000 SERIES load bank, please contact a member of our sales team.