Avtron Power Solutions Digital Binder
Model 8200 Specifications
1
2
3
4
5
6
7
8
MAINTENANCE ACCESS SIDE DOORS
A
A
STATIC - x1 BLANK ALUMINUM GLAND PLATE - APERTURE 300[11.8] X 300[11.8]
HOT AIR DISCHARGE
HOT AIR DISCHARGE
HOT AIR DISCHARGE
HOT AIR DISCHARGE
HOT AIR DISCHARGE
HOT AIR DISCHARGE
WALK IN CONTROL ROOM
2591 [102.0]
B
B
COOL AIR FLOW IN
COOL AIR FLOW IN
COOL AIR FLOW IN
COOL AIR FLOW IN
COOL AIR FLOW IN
394 [15.5]
650.5 [25.6]
x8 ELECTRICAL OPERATED AIR INLET LOUVRES
MAINTENANCE ACCESS DOORS
MAINTENANCE ACCESS DOORS
705 [27.8]
2677 [105.4] CABLE ENTRY GLAND PLATE POSITION
2632 [103.6]
5855 [230.5] FIXING CENTRES
2260 [89.0] FIXING CENTRES
LOUVRE MAINTENANCE DOOR FOR OPERATING MECHANISM
2050 [80.7] FORK LIFT POCKET CENTRES
C
C
CABLE ENTRY - BOTTOM CABLE ENTRY - APERTURE 960[37.8] X250[9.8]
3029 [119.3]
300 [11.8]
FORK LIFT POCKET DETAIL
2438 [96.0]
D
D
CABLE ENTRY DETAIL
1905 [75.0] DUCT OPENING
115 [4.5]
LOCKABLE LIFT UP CABLE ENTRY DOOR
1093 [43.0] DUCT OPENING
355 [14.0]
288 [11.3]
6058 [238.5]
605 [23.8]
E
E
NOTE : 2M OF CLEAR SPACE SHOULD BE LEFT AROUND THE LOADBANK FOR COOL AIR INLET AND MAINTENANCE ACCESS. AT LEAST 5M SHOULD BE LEFT CLEAR BETWEEN HOT AIR OUTLET AND ANY SURFACE.
FOR MAIN POWER AND FAN & CONTROLS CABLE ENTRY x2 APERTURE - 605[23.8] X 288[11.3] STATIC - x2 BLANK ALUMINUM GLAND PLATE
All dimensions are in millimeters. Specifications subject to change without notice.
8500 KGS / 18740 LBS
APPROX WEIGHT - 8200
© NJ Froment & Co. Ltd. This document may not be copied or disclosed in whole or partwithout prior written authority.
REVISION HISTORY
NJ Froment & Co Ltd Easton on the Hill STAMFORD - PE9 3NP - UK Tel: +44 (0) 1780 480033 Fax: +44 (0) 1780 480044 loadbanks.ascopower.com
8200 GENERAL_ARRANGEMENT_STATIC
CAD Code. 8200 Part Number. N/A Drg No. Sheet
F
F
DESCRIPTION
REV
DATE
APPROVED
Drawn - RPM
Date - 14/07/2021
1_OF_1 GAS8200A01
Checked - Date - Approved - RPM Date - 16/02/2022
Scale. NTS 1st Angle Projection
Dims. mm[in]
1 Internal Single Phase Socket Outlets The control room is equipped with single phase socket outlets. These may be used to power a PC to operate the load bank. International load banks are fitted with two sockets. One is a 13 amp square pin, the other a European round pin socket. One 5 amp RCD protection device backs both units. Load banks to North American specification are supplied with one US type 2 flat blade and earth socket backed by a RCD protection device. Options Power Isolation Power air circuit breakers complying to IEC standard allow the load bank to be fully isolated from the supply on test. The circuit breakers provide short circuit, overload and earth fault protection. A shunt trip facility is also fitted to allow tripping from a remote location. Dual UL/IEC standard circuit breakers are also available. 2
4 Documentation – Operator Handbook
7 Additional Information An extensive range of resistive, inductive, capacitive or combined load banks of varying capacities are also available. For further information on this model or any other 8000 SERIES load bank, please contact a member of our sales team. 8
3
5
6
A comprehensive illustrated operator’s manual is supplied. Sections cover safety, installation, commissioning, operation, calibration, maintenance and fault finding. Testing and Standards Functional operation and load tests are completed on all load banks, before despatch, in line with our ISO 9001:2008 procedures. Avtron load banks comply with international standards and are CE marked to confirm compliance with both the EMC and Low Voltage Directives.
Weight and Dimensions Measurements: mm/in. and kg/lbs. Model 8200 Length 6100/240.15 Width 2440/96.06 Height 2590/101.97 Weight
Dependent on capacity
Avtron Power Solutions NJ Froment & Co Ltd, Cliffe Road, Easton-on-the-Hill, Stamford, PE9 3NP, UK
www.avtronpower.com customercare@avtronpower.com • +44 (0) 1780 480033 ©2023 Avtron Power Solutions. Publication 5022 • Rev. K